The test stand performs performance test on various automotive gas hoses according to relevant standards such as GMW14908, GMW16153 and B32 7128. Includes hose resistance characteristics and leakage test under specified technical conditions. The test stand has automatic data acquisition and processing functions, after setting the test working condition, it is automatically adjusted by the computer. For the hose resistance characteristic test, the corresponding resistance characteristic curve can be generated by the computer based on the test data. For the leakage test, not only the leakage under the specified working conditions can be measured, but also the leakage curve under different working conditions can be generated by the computer.
Test stand technical parameters are as follows:
Test medium:Air
Maximum air flow range (Standard condition): 500 kg/h
Maximum allowable pressure loss (Standard condition):2500 Pa
Thermostat environment temperature adjustable range:-40℃~+150℃
Maximum inflation pressure: 0.35 MPa (G)